Legacy carrier adapter: nominal geometry record

12 October 2026. Adapter r0.1.0, concept-unvalidated. Automated source/mesh inspection with OpenSCAD 2021.01, Python 3.12 and trimesh 5.1.1; reviewed in this change. This records nominal geometry, not received print acceptance.

The instructions define the tested interface, configuration, bought hardware and reversible trial sequence. Reproduce with:

python3 scripts/corner-support/check-legacy-adapter.py

The checksum-pinned text fixture is the complete old carrier source from 84f3b52829cafc73c5765cd619a582c97f770439, with SHA-256 414defcdde68792a9b994532f13a3684e8a735dc89273652185e520b0ae2923b. Only its library include is redirected when meshing. This makes the frozen interface comparison independent of Git history availability in CI/packs.

Check Observed nominal result
Frozen carrier vs original source Zero nearest-vertex deviation in all five variants; boolean volume roundoff 0.006–0.236 mm³, within the recorded numerical tolerance
Variants Round 100/120/140 with 1.5 mm line; round 120 with 4.5 mm line; square 100 with 1.5 mm line
Each adapter half One connected, watertight solid; consistent winding; positive volume; approximately 8.327 cm³
Public print entrypoints Flat bed at nominal Z0; 40.6 × 57 × 7.4 mm bounds; same volume/pose as installed halves after rigid transform
Socket vs each old carrier 0 mm³ overlap
M8 fastener stack vs carrier/adapter 0 mm³ overlap
Native 4.7 mm pin vs adapter 0 mm³ overlap; M8 in native bore rejected
Block vs adapter, carrier and extra fastener 0 mm³ overlap at 0/15/30/45/60/75/90° in the nominal pin plane
Simple bush at the original pin point Rejected: approximately 314.900 mm³ reconstructed block/old-lug overlap at 45°
Round-120 passive sheave centre X237.55/Z100.3015; nominal vertical winch tangent retained; horizontal span 35 mm lower than r1.0.0

The generated JSON records hashes for the exact source dependencies and checker, plus per-variant results. The standard BOM volume capture also refreshed the 79 existing costed fabrication meshes; the temporary kit is optional and has no invented material or commercial estimate.

The broad local command pnpm cad:check -- --require-openscad passed static validation for 165 registered models but exceeded its 120-second per-export limit on the unchanged winch-drum-passive-1. The two new print entrypoints were independently compiled and inspected by the adapter checker; full repository CAD compilation remains a separate CI check.

Block neck/detail surfaces, threads, actual print clearances, pin/ring locking, groove seating and line fleet angle remain unmeasured. These results establish neither strength/creep nor loaded or outdoor operation. Physical tests must record the actual parts, print process, equipment, conditions and reviewer; retain the head acceptance gates.