Corner support printed-head acceptance record
Commissioning record: r1.2.0 carrier halves / measured Barton interface; rear pads and covers r0.3.0 with concealed printed slides/latches; unchanged marking template r0.1.0. Owner dimensions are evidence for the reference model, not completed station acceptance. No physical test has been performed by this change. Record one form per station and link approved calculations, as-built drawings, print records and dated test records. Empty fields remain unverified. Successful CAD exports and mesh checks do not fill them.
| Required record | Measured value / document / reviewer |
|---|---|
| Station ID and variant: passive, powered, dock; printed or separate metal alternative | Pending |
| Selected CAD parameters, model revisions and source/mesh hashes | Pending |
| Post section at both rows, taper/ovality, material/treatment, moisture | Pending |
| Site survey: pulley centre, pole axis, bed frame, guy anchor, access zone | Pending |
| Carrier/pad material, manufacturer/lot, drying and conditioning | Pending |
| Printer/nozzle, orientation, layer height, walls/infill, temperatures, enclosure, supports/seams | Pending |
| Slicer support plan beneath carrier webs 20.2 mm above bed; rear pads printed on original lower face with main body on bed and localized supports for rearward catch bridge/horizontal M12 bore; support-removal inspection of undersides, follower/catch roots, structural holes, guide lips and latch beams/hooks | Pending |
| Printed dimensions, fit allowance, hole finishing, voids/layer inspection and retained wall/edge dimensions | Pending |
| M12/M8 bolt grades/lengths, washers/nuts, locking engagement, protrusion and tool/cover clearance | Pending |
| Reviewed clamp process/preload; carrier/rear-pad pressure, timber contact and settlement | Pending |
| Received BA01090 identity, tang gap, pin diameter/usable length and locking | Owner report 2026-10-11: N01090/BA01090, 15.8 mm gap, 4.7 mm pin, 1.5 mm tangs. Usable length and fitted locking: pending |
| Pin-to-sheave separation, actual block pose/articulation over span angles and unequal tensions, groove/side gaps | Owner-reported 42 mm centre spacing. Actual pose/articulation, groove and side gaps: pending |
| Compatible bought pin dimensions/rating, terminal-lug bearing, pin bending, articulation and locking | Pending |
| Fitted removable keeper: gap, full line sweep, slack/derailment behavior | Pending |
| Winch drum tangent depth, loaded deflection and lateral alignment across winding travel | Pending |
| Cosmetic cover print process, intact fascia, open rib-channel fit and drainage | Pending |
| Smooth exterior with no cover hardware or fastening holes; actual T-guide clearance, stop seating, latch engagement and underside release access | Pending |
| Cover insertion/release force, latch fatigue and creep, follower/guide cracking, vibration retention and repeated removal; release from below then front -Z190/+Y100 or rear -X80 with structural bolts untouched | Pending |
| Reviewed bought guy-to-post connection dimensions/height/rating and timber load path | Pending |
| Wire, thimble, clamp specification/count/spacing/tails and turnbuckle locking | Pending |
| Maximum span/winch tensions, angles, dynamics, wind, fault and dock cases | Pending |
| Printed web/root/lug/bolt-bearing and interlayer analysis; joint slip, pad pressure and residual transverse load | Pending |
| Worst-case temperature/moisture/UV conditions and sustained-load creep limits/procedure | Pending |
| Complete-head proof directions/load/duration, cycling/reversal count and calibrated load equipment | Pending |
| Recorded deflection, slip/permanent set, creep, fastener retention and pre/post-test cracks/holes/timber | Pending |
| Soil, embedment and anchor review; approved proof procedure and quantitative movement limits | Pending |
| Dock combined loads, capture/parking/retention and service access | Pending |
| Powered line bending/electrical/fatigue; box/cable/thermal/weather review | Pending |
| Material/contact/corrosion review; printed guide/latch outdoor aging and maintenance | Pending |
| Inspection interval, settlement recheck, quantitative discard and replacement criteria | Pending |
| Requalification policy for material, printer, orientation or slicer changes | Pending |
| Dated result, reviewer and authorization for named stage/configuration/load | Pending |
Stop before loaded installation while printed-process qualification, compatible pin, fitted keeper, guy attachment, structural/site review, soil/anchor tests or stage authorization is missing. An unloaded bench fit mock-up may record measurements under the reviewed procedure; it does not clear loaded/overhead acceptance. Preserve failed results and discarded parts as evidence.
For a historical metal variant, record the actual angle/bend/factory holes, metal-saddle grade/process/contact, plate perforations, corrosion and its own fastener stack as additional variant-specific evidence. Metal geometry or its earlier nominal checks do not qualify the printed head.