ARBI
Documents / docs/assemblies/dock/lower-enclosure.md

Removable charcoal dock underside

15 October 2026. Nominal CAD candidate; physical acceptance pending.

The lower enclosure extends the selected dock appearance with a continuous charcoal bowl beneath the warm-white crown. It conceals the locator and upper guide attachment from side views while leaving the lower flared guide and downward capture mouth exposed. It is a removable cosmetic shelter, separate from the pod-retention load path. The current guide, locator, fork, stud, bridge and arm retain their interfaces.

Geometry and print inventory

Four cardinal panels meet at the 45/135/225/315 degree cable axes, with 18 mm edge-open radial passages. Print three dock-lower-panel pieces for 0/90/270 degrees and one dock-lower-rear-panel for 180 degrees; both are revision 0.1.0. The rear panel faces the post and includes the arm/fork opening. The roof quadrants and assembled reference become revision 0.3.0; the guide remains 0.2.0 and stud 0.1.1. Reprint four white roof quadrants and add these four charcoal panels. Inspect the retained prints and received hardware before reuse.

In the existing dock frame, the tapered body runs from Z105–171 with outer diameter 140–283 mm. The nominal wall is 2.8 mm normal to the slope, formed by a 4.128 mm radial inset. At Z105 the inner opening is approximately Ø131.744 versus the guide's nominal Ø126.636 outer diameter, giving about 2.55 mm radial separation before faceting, print tolerance or deflection. The rounded 300 mm R40 top tray occupies Z171–174, has a Ø148 center opening and ends 1 mm below the white roof skirt at Z175. The enclosure must not become a rubbing surface or a second stud locator.

The rear panel has a 70 mm wide opening, local Y=-35–35, from Z118 through the tray top. It clears the arm and manual fork route; remove the rear panel for complete hand/tool access. Open cable seams and the rear opening also leave runoff, air and inspection paths. They do not create an ingress rating or demonstrate wind-driven rain protection.

Use the supplied print-coordinate meshes: rotate the cardinal sector 45 degrees about Z, then turn the top tray onto the bed by 180 degrees about X. Review the full slice, support contact/removal and the actual printer envelope; inspect the thin wall, tray, lip, cable seams, rear opening and bolt holes. The nominal bed check does not establish support-free manufacture. The exported ordinary and rear panel print poses each occupy approximately 185.496 × 185.496 × 69 mm before supports, brim and other slicer exclusions.

Dedicated fastening

Each panel has two dedicated M3 × 25 socket-head bolts, two Ø7 × 1 mm washers per bolt and one DIN 985 locking nut per bolt. The nominal nut dimensions are M3, 0.5 mm pitch, 5.5 mm across flats and 4 mm high, from the supplier's DIN 985 drawing checked on 15 October 2026. This is a dimensional reference, not a selected supplier offer or proof of received-part fit. One dock adds eight bolts, sixteen washers and eight locking nuts, bringing the provisional bought-hardware set to 132 pieces. These fasteners retain only the appearance enclosure. Do not remove the M4 guide/carrier or roof/carrier/arm fasteners to service a black panel.

The eight axes are (+/-141,+/-60) and (+/-60,+/-141) in dock coordinates. The nominal upward stack is Ø5.5 × 3 mm bolt head Z167–170, lower washer Z170–171, panel tray Z171–174, roof boss contact at Z174, upper washer Z185–186 and locking nut Z186–190. The M3 × 25 bolt bears at Z170 and ends at Z195, leaving approximately 5 mm beyond the nut. Ø16 roof bosses extend Z174–193 and directly contact the panel tray; there is no gap inside the clamped contact stack. The 1 mm perimeter shadow gap remains between the panel top Z174 and the white outer skirt Z175, away from these contacts.

Roof bosses incorporate side-loaded captive nut pockets. Measure the received head, washer, nut and locking-zone envelopes; inspect full locking engagement, the pocket restraint and tool access. Printed bosses and captive pockets require material/process, pull-through and creep evidence. No torque or retention force is inferred from screw diameter or nominal projection. The nominal nut pocket has 6.9 mm circumdiameter, with a 5.9 mm wide × 4.2 mm high entry. Review as-printed clearance and anti-rotation restraint.

Installation and service

Keep the dummy independently supported throughout this unloaded bench procedure. Fit the rear panel at 180 degrees and ordinary panels at 0/90/270 degrees, preserving open cable seams, rear arm clearance and the downward guide mouth. Install their dedicated fasteners only after checking the assembled gaps and nut pockets.

For removal, undo the panel's two dedicated M3 bolts and remove their two lower washers. Keep every other panel's bolts/lower washers fitted, and leave all upper washers and locking nuts in the roof pockets; they are fixed obstacles during withdrawal. Support the panel and use its sampled nominal path:

  • Ordinary panel: move 110 mm outward horizontally in its cardinal direction, then lower 100 mm.
  • Rear panel: move 60 mm toward the post, lower 20 mm, move another 50 mm toward the post, then lower another 80 mm. Its cumulative displacement is 110 mm outward and 100 mm down. The intermediate drop clears retained M8 arm-lap hardware; a straight outward rear move is obstructed.

The generated mesh check passes these discrete poses; it does not prove continuous or physical clearance. Do not pull a panel straight down around the flared guide. Remove the rear panel before manually working on the fork or inspecting the enclosed core. Reverse the checked path to install and inspect all fits afterward.

Remove all four black panels before the existing roof service procedure: slide the eight upper washers and eight nuts inward out of the now-accessible roof pockets, then independently support dummy and locator and remove roof-stack/seam hardware. Lift one white quarter 60 mm and translate it inward 100 mm along its diagonal. Roof service changes the shared carrier/arm fastener stack; black panel service does not. These procedures do not authorize loaded or installed service, nor establish actual hand, harness or sloping-line clearance.

To reassemble, reverse the roof procedure, insert upper washers/nuts into the accessible pockets with black panels absent, fit the panels and install their bolts/lower washers. Do not require hidden upper nuts to be removed before withdrawing a panel.

The white crown now prints mounting-seat down from its Z174 boss contacts; support planning must include the perimeter one millimeter above that plane.

Nominal stationary dead load

The exported ordinary panels have 86.435493 cm³ solid volume each; the rear panel has 54.244505 cm³. Three ordinary panels plus one rear panel total 313.551 cm³. The fabrication catalog assigns PETG Matte at 1.37 g/cm³ to the charcoal panels and white crown. These are solid CAD estimates before slices, supports or measured prints.

The rear opening removes material asymmetrically. Combining the actual installed panel meshes gives a lower-enclosure center of mass at X=+11.253671 mm, Y=0, Z=158.701054 mm. Its gravity lever from the post face is therefore 0.401254 m, rather than the dock axis's 0.390 m. Four identical white quarters remain symmetric about the dock axis. With g=9.80665 m/s², calculate grams as volume×density, convert to kilograms, then use moment=mass_kg×g×lever_m:

Stationary appearance parts Solid volume Estimated mass Gravity lever Post-face moment
Prior rounded crown 0.2.0 367.132 cm³ 502.971 g 0.390 m 1.924 N·m
Current crown 0.3.0, four quarters 392.062 cm³ 537.125 g 0.390 m 2.054 N·m
Four charcoal lower panels 313.551 cm³ 429.565 g 0.401254 m 1.690 N·m
Added bosses and lower panels 338.481 cm³ 463.719 g Component-specific 1.821 N·m

The prior geometry/recipe is from source commit b3bdd81a8bd8ca16a1e53eba17b8820208571650. This estimate excludes the new eight bolts, sixteen washers and eight nuts, retained spacers/hardware, arm, pod, cable tensions, wind, contact and service forces. It records one LC-05 contribution, not an allowable load or proof of arm/post capacity. Use actual slices/materials and all reviewed forces before physical load testing or installation.

Nominal evidence and remaining acceptance

The 15 October 2026 local generator run passed 54,082 nominal geometry checks for DOCK-IF-01, non-powered round-120, with the independently supported dummy configuration. OpenSCAD 2021.01 exported thirteen connected, watertight fabrication meshes and their checked print poses. The canonical dock library SHA-256 for this record is 7d3a8e5251cef8fc9409373bb50c6dd38fb7456012bd32737b75354273f8bd32. The generated geometry-report.json preserves registry, entrypoint, library, source and mesh hashes plus the exact installed transforms.

  • Ordinary panels pass 22 sampled poses each: 0–110 mm outward in 10 mm increments, then 10–100 mm down at full outward displacement. The rear panel passes 24 poses, with the 20 mm intermediate drop sampled in 5 mm increments. Only its own bolts/lower washers are absent; all other panels, upper washers/nuts, structural hardware, represented pod, post and four Ø1.5 mm lines from Z=-200–800 remain fixed obstacles.
  • Upper washer/nut insertion and reverse extraction pass at 30/20/10/5/2/1/0 mm from their seats, with black panels and dedicated bolts removed. Local Ø5 × 80 mm axial driver envelopes beneath all eight bolt heads clear the represented assembly. This does not establish hand or complete tool access.
  • Three ordinary-panel sections at Z115/135/160 measure 2.7902/2.7989/2.8098 mm normal wall thickness; the sampled tray is 3 mm. Seven crown/skirt sections remain 2.8000–3.1734 mm. These values apply only to those sections.
  • Existing roof-quarter service, fork travel, the 0.2 mm flat-shoulder gap and full represented pod release pass their nominal regressions. Roof service first removes all black panels and their dedicated hardware, then samples 60 mm upward and 100 mm inward against the retained core and long lines.

Deliberately obstructed controls produce positive mesh intersections:

Control Intersection volume
Closing a lower cable seam 11.902 mm³
Closing the rear arm window 7,544.278 mm³
Lowering a panel before outward withdrawal 517.737 mm³
An incomplete circular washer pocket 6.028 mm³
Straight rear withdrawal into retained M8 lap hardware 274.154 mm³

The existing closed-fork, uncut-guide and closed-roof-slot controls also remain positive. These control volumes demonstrate detection of the modeled obstructions; they are not contact areas, forces or physical damage results.

The booklet builder and its independent ZIP checker own regenerated meshes, nominal collision checks, print poses, hardware stacks, service samples and control failures. Exact volumes, mesh identities and check results are recorded in the generated pack. Nominal source consistency remains separate from physical acceptance.

The kit remains concept-unvalidated and restricted to an independently supported dummy. Review the actual slices/materials, extra wind and dead load, fastener/pocket strength, print creep, rain/runoff/condensation, service access and full line/harness sweep through the bench plan and acceptance record. Automatic capture, actuator, observations, complete pod mass and all-line power-loss restraint remain separate unresolved gates.