ARBI
Documents / docs/assemblies/corner-station/geometry-check.md

Printed corner head nominal geometry record

Historical r0.1.0 record. For the measured Barton interface and current carrier revision see the 11 October geometry record. The tie-free cover contract defines the r1.2.0 carrier / r0.3.0 pad-and-cover interfaces and current verification requirements. The results below retain their original geometry and do not describe those revisions.

8 October 2026. New printed models r0.1.0, concept-unvalidated.

The package builder exports the registered printed carrier halves, rear pad, cosmetic covers and shared marking tool with OpenSCAD 2021.01. Every written STL is read back for positive volume, watertightness, winding and connected-body checks. Round-100/120/140, square-100 and nominal powered-4.5 configurations remain separately identified.

Nominal checks compare the carrier/pads/covers with the represented timber, M12 through-bolts, M8 cross-bolts, washers, nuts, provisional received block, pin, line and cosmetic straps. The current report records sampled cosmetic service paths (front -Z190 then +Y100; rear -X80), removed-cover tool access, matching halves, installed and print transforms, per-configuration bounds and bolt-stack engagement. The top chord is structural; it is not a lift-off weather roof. No collision sample permits removing a loaded carrier half.

The tangent comparison reads the canonical winch's axis height, effective drum diameter and post surface, then compares that independent result with the exported corner line. The report records rounding tolerance, both winch tangents and dependent winch source hashes. Nominal tangent agreement does not establish actual pulley freedom, lateral fleet angle or loaded deflection. The current nominal block pose is 45° about its Y pin, with a provisional 40 mm pin-to-sheave separation, equal leg tensions and a horizontal +X span. The pin and sheave centres therefore have distinct X/Z coordinates; an upright block envelope is not the equal-tension alignment reference. Other span angles, unequal tensions, friction and received articulation remain unverified. An independently transformed vertical block mesh matches the installed pose. The synthetic 10 N reaction produces zero moment at that pose; the rejected vertical block leaves 400 N mm. This is an equilibrium arithmetic check for the represented geometry, not a received-hardware or motion test.

Independent negative controls reject insufficient M12 × 180 engagement in the printed stack and the historical round-120/150-angle tangent mismatch of 42.55 mm. Synthetic vector statics checks right-angle resultant, unilateral guy reaction, transverse load and eccentric ground moment. These are arithmetic references without an operating load limit or material capacity calculation. One-cubic-millimetre material probes in both halves verify that root through- bolt cutters do not remove the terminal lug, and the short central pin cutter does not perforate the outer webs. Separate void probes verify the pin bore remains open. Negative controls reproduce both incorrect long cutters, an unrelieved fascia collision and the rejected +X40/+Y5 front-cover path.

The PDF and GLB use actual exported meshes, recorded filenames, product-role colors and installed/exploded transforms. Archive validation checks registered filenames, current source/mesh identity, figure references, PDF status/page information and file hashes. Inspect every rendered PDF page separately for legibility. Generated geometry-report.json and manifest.json identify the exact source/mesh revision; rerun builder/checker after source changes.

Execution status

Local nominal execution on 8 October 2026 used Node.js 24.15.0 and OpenSCAD 2021.01. pnpm cad:check -- --require-openscad compiled all 99 registered entrypoints. The printed package builder passed 1,785 nominal checks across all five named configurations and produced 95 STL files: fabrication meshes, print poses, bought-part references and vertical-block controls. Every single part's longest print dimension was at most 205 mm, within the checked 256 mm envelope and 5 mm XY edge reserve. This excludes slicing/support clearance.

The eight-page A4 guide was rendered page by page and inspected for legibility, figure correspondence, clipping and overlap. The matching generated report contains exact mesh/source hashes, per-configuration bounds and controls. Run python3 scripts/check-booklet.py hardware/generated/corner-support --variant corner against the final pack to verify current source/ZIP identity; an older archive with matching filenames is insufficient. The historical metal-head execution record does not qualify these printed load-bearing parts.

These checks cannot establish layer bonding, anisotropic strength, fastener pressure, sustained-load creep, fatigue, outdoor temperature/conditioning, printer quality, actual timber contact/preload, received double-tang/pin fit, thin-line keeper retention, guy connection, soil, wind or installed capacity. The acceptance record keeps those physical/process requirements open. Nominal geometric contact is not a pressure, clamp-friction or structural qualification.