Documents / docs/operations/weather-parking-and-maintenance.md

Weather, parking, and maintenance

Operating policy

The pod returns to its high HOME dock whenever it is inactive. The dock is the primary weather shelter; the pod rain cap is only brief splash/direct-rain protection.

The V1 baseline deliberately does not use an anemometer or numeric wind-based operating limit. At the same time, it says not to start work when adverse weather is expected or observed. The mechanism that makes that decision is currently undefined. Until a validated local policy or sensing/integration exists, inability to determine acceptable conditions is a stop condition.

Inactive and weather sequence

flowchart TD
    IDLE["Capture complete or inactive"] --> RETURN["Return toward HOME"]
    WEATHER["Adverse or unknown conditions"] --> REJECT["Reject new captures"]
    REJECT --> ABORT["Complete or abort current move safely"]
    ABORT --> RETURN
    RETURN --> DOCK["Slow PRE-DOCK approach and latch"]
    DOCK --> CONFIRM["Confirm mechanical capture"]
    CONFIRM --> PARKED["Park with only approved line tension"]

Strong wind, lightning risk, rain beyond the approved pod exposure, ice, visibility loss, unusual line motion, or other conditions outside the validated envelope prohibit a new normal capture. The safe response to a condition first detected during motion must be defined by scenario; “always go home” is not safe if the path or dock has become unavailable.

High parking versus ground-level service

Normal automatic parking remains at the high dock:

  • target capture point approximately 2.65–2.70 m;
  • target bottom of docked pod approximately 2.4–2.5 m;
  • the pod stays out of normal head space while inactive.

Servicing without a ladder is handled separately. A manually initiated Maintenance state may lower the pod only after:

  1. the work area is physically cleared and controlled;
  2. remote and scheduled jobs are inhibited;
  3. stored mechanical/electrical energy and recovery behavior are understood;
  4. an operator intentionally authorizes the move;
  5. the system uses reduced, bounded motion to an approved service position;
  6. isolation/lockout is applied before hands enter hazardous areas.

The controller must never enter below-head-height maintenance positioning automatically. Failure recovery must not improvise a low position.

Parked line policy

V1 does not intentionally slack the four positioning lines. Repository starting values are:

  • minimum line height over accessible work or walking areas: at least 2.2 m;
  • initial parking-tension experiment: approximately 10–20 N per line;
  • actual value chosen from installed measurements, with special attention to the heavier powered line.

The dock latch supports the pod, while the powered winches currently preserve line clearance. Because a normally engaged brake is deferred, total-power-loss line sag is unresolved. Public operation may require bringing a fail-safe brake or other passive clearance control into V1.

Weather readiness

Before each operating period, confirm:

  • conditions are inside a locally defined, evidence-backed envelope;
  • no lightning or surge-related stop condition is active;
  • lines, posts, guys, anchors, dock, and shelter show no storm damage;
  • the pod, dock, pulley keepers, and enclosures are dry/drained enough for approved operation;
  • fiducials and optical surfaces are visible and usable;
  • no ice, debris, plant growth, or foreign object enters a line, winch, dock, or workspace;
  • site access and exclusion controls are effective.

Remote weather forecasts may be one input but cannot prove local line/wind conditions.

LS-14 and LS-15 assign local weather/access permission, validity and failure behavior. The BOM's weather-sensor entries are deferred, not evidence of fitted sensors; this requirement does not change V1's anemometer selection. A reviewed local observation/inspection or sensing policy must define the accepted envelope and expiry. Weather readings remain unavailable until a reviewed interface and measurements exist; unknown conditions inhibit dependent operation.

Routine inspection

Define intervals by elapsed time, travel/cycle count, exposure event, and observed condition. At minimum inspect:

  • posts, soil movement, guys, anchors, brackets, backing plates, bolts, shackles, pulleys, and corrosion;
  • Dyneema, powered conductors, terminations, guides, slip ring, sag, and calibration drift;
  • drums, couplings, bearings, guards, home switches, motors, drivers, and abnormal sound/heat;
  • pod chassis, line attachments, docking stud, gimbal, ribbon, fasteners, converter, capacitor, connectors, cap, and optics;
  • dock arm, funnel, latch, spring, pins, release, sensor, roof, drainage, and debris;
  • cabinet protection, seals, terminals, earthing/bonding, labels, moisture, heat, and event logs;
  • fiducials, site reference points, paths, privacy/exclusion zones, and vegetation encroachment.

Every inspection identifies the released assembly revisions and records pass, measured result, observation, action, and reviewer. “Looks fine” is not enough for critical discard criteria.

Maintenance controls

  • Prevent remote, scheduled, or automatic start during maintenance.
  • Isolate and verify relevant electrical energy.
  • Control line tension and mechanical stored energy before opening guards or removing parts.
  • Never work below suspended hardware or loaded test equipment.
  • Recalibrate after changes that affect geometry, line length, drum radius, camera, gimbal, anchors, or dock.
  • Run bounded post-maintenance tests before restoring the full operating envelope.
  • Replace parts by stable ID and compatible revision, not appearance alone.

Return to service

Return to service requires:

  • completed work and inspection records;
  • all guards, retention, protection, seals, and labels restored;
  • compatible configuration/calibration loaded;
  • no unresolved critical observation;
  • safe homing/recovery and dock test at reduced limits;
  • required electrical or structural retest;
  • deliberate release from maintenance by an authorized operator.

Acceptance evidence

  • Defined local environmental operating and parking envelope.
  • Reliable rejection of new work and bounded response to weather changes during each state.
  • Repeated high docking and safe manually controlled maintenance access.
  • Measured parked line clearance in normal and relevant fault/power conditions.
  • Inspection intervals and discard criteria supported by material/component evidence.
  • Demonstrated remote-start inhibition, isolation, lockout, and post-maintenance release.
  • Storm/event inspection and recovery procedure.

Open questions

  • How are acceptable wind, rain, lightning, temperature, and ice conditions determined locally?
  • What is the safe action when the dock is inaccessible during deteriorating weather?
  • Is passive braking required to preserve line clearance through total power loss?
  • Which inspections can use telemetry, and which require physical access and measurement?
  • What maintenance position and restraint provide safe ground-level service?
  • How often do UV-exposed line and printed parts require replacement?