Desk feet geometry check - 2026-09-27
Models: winch-desk-foot-short and winch-desk-foot-long, revision 0.1.0.
State: concept-unvalidated. Automated geometry check; physical inspection
and human engineering review remain outstanding.
Configuration: passive 550 x 180 x 8 mm plate, 50 x 120 mm post-hole pattern,
35 mm foot height, 9.2 mm bolt passage and 26 x 27 mm underside nut recess.
Reference mount geometry: commit d8235b0.
OpenSCAD 2021.01 exports and the mesh checker reported:
| Check | Short foot | Long foot |
|---|---|---|
| Bounding box, mm | 160 x 60 x 35 | 244 x 60 x 35 |
| Connected components | 1 | 1 |
| Triangles | 1564 | 1564 |
| Closed, consistently oriented manifold mesh | Pass | Pass |
| Non-degenerate triangles and positive volume | Pass | Pass |
| Solid CAD volume, cm3 | 74.28 | 105.80 |
A Boolean intersection check of all four installed feet against eight 20 mm diameter fastener envelopes, extending 25 mm below the plate, returned an empty intersection. This checks nominal geometry only; measure the actual protruding fasteners and inspect the printed parts.
Reproduction
Use OpenSCAD 2021.01, Python 3 and NumPy:
python3 scripts/check-winch-desk-feet.py
pnpm cad:check -- --require-openscadExports and the collision model are generated in a temporary directory. This record does not establish print quality, bolt clamping capacity, stiffness, desk friction, tipping resistance or suitability for tensioned cable tests.