ARBI
Documents / hardware/assemblies/winch/coupling-cover-geometry-check.md

Coupling-cover clearance check — 2026-09-27

Configuration: coupling cover and mount reference 0.1.1, motor stand and bearing parts 0.1.0, drum fabrication parts 0.1.0. Status remains concept-unvalidated. The owner reported that motor mounting screws, washers and nuts prevent the 0.1.0 cover from seating. No dimensions of the received fasteners were supplied; the envelope below is a documented design allowance.

Change and compatibility

The original cover had a 48 mm-wide internal cavity with its roof 24 mm above the shaft axis. Motor mounting centres are at Y/Z=±23.57 mm, with ±2 mm vertical adjustment, so a normal washer overlaps the walls and roof near the stand.

Revision 0.1.1 adds a wider, open-bottom motor-end cavity. It accepts four 12 mm-diameter fastener envelopes projecting 14 mm from the coupling-side stand face, including screw tips. It adds 1 mm radial/axial clearance and preserves the entire ±2 mm motor adjustment. The recess is 61.14 mm wide, extends 32.57 mm above the shaft axis and is 15 mm deep. Its side/top/forward walls are 3 mm thick. The existing front shell remains 4 mm thick. The stand and cover attachment centres are unchanged, so only the cover needs reprinting.

Print bounds are 65.57 × 86 × 39 mm in the exported orientation; the motor-facing flange remains on Z=0. Check the new internal step in the slicer. Mount it with four M4×20 screws, eight 9 mm OD washers and four locknuts. The minimum lateral gap to the modelled cover-washer envelope is 0.43 mm.

Independent checks

The mesh checker loads current registry output names and uses trimesh/manifold boolean intersections. It checks:

  • One watertight body, positive volume, build-plate contact and print bounds.
  • The convex hull of the motor-fastener cylinders at both adjustment limits.
  • The original cover as a regression control: 3624.095 mm³ of total overlap with the motor hardware envelope, required to fail clearance.
  • Revised cover versus those envelopes: no overlap above 0.001 mm³.
  • Cover removal/installation at 1 mm increments over a 0–70 mm vertical lift: 284 motor-fastener checks per configuration passed.
  • Four cover screw-head/washer envelopes, motor, bearings, collars, spacers, coupling, printed supports and full-revolution drum rod/nut sweeps: 665 passive and 684 powered component-pair checks passed.

Reproduce with current exported models:

python3 scripts/check-winch-mount-meshes.py hardware/generated/booklet/models/arbi hardware/generated/booklet/models/arbi

OpenSCAD 2021.01 compiled all 23 registered entrypoints with pnpm cad:check -- --require-openscad. BOM regeneration and pnpm bom:check passed with the existing 232 procurement-incompleteness warnings. Local Markdown link validation passed. The 14-page booklet was rebuilt from these STL exports and every page was rendered for visual inspection.

The older mount check remains a historical 0.1.0 record; it did not include motor mounting hardware. The new check addresses that omission. It uses nominal envelopes, not a scan or measurement of the actual fasteners, and samples a straight vertical installation path. It does not prove fit after printing, unrestricted tool access, strength, guarding performance or thermal endurance. Dry-fit the revision before any powered test.