ARBI
Documents / hardware/assemblies/corner-station/pole-pulley-mount-check.md

Round-pole mount nominal CAD record

Historical r0.1.0 generic-eye record. Current front/assembly r1.0.0 uses the measured Barton double tang; see the new geometry record. The original results below are preserved and do not describe the new interface.

Revision 0.1.0, concept-unvalidated, 7 October 2026.

This record covers only the split-clamp proposal, using OpenSCAD 2021.01 and nominal geometry. Physical material, clamp slip resistance, loads, received-part fit and installed operation remain unverified.

Export and geometry checks

python scripts/build-pole-pulley-concept.py exports both custom halves at pole diameters 100, 120 and 140 mm. All other dimensions remain at the r0.1.0 defaults. Six exported meshes were each a single watertight solid with positive volume and collar bottom at Z=0. The front is one connected solid, including both arms.

Pole diameter Front envelope X × Y × Z Rear envelope X × Y × Z
100 mm 173.5 × 172.5 × 90 mm 58.75 × 172.5 × 90 mm
120 mm 183.5 × 192.5 × 90 mm 68.75 × 192.5 × 90 mm
140 mm 193.5 × 212.5 × 90 mm 78.75 × 212.5 × 90 mm

Independent mesh booleans at each diameter found less than 0.001 mm³ overlap between the front/rear pair and between either half and the nominal pole, four M8 clamp shanks and their Ø18 mm washer envelopes. The attachment-pin shank and the nominal 22 mm eye/spacer opening also cleared the front part. Washer and eye envelopes are shortened by 0.02 mm to distinguish intentional face contact from penetration. This is a numerical test allowance, not a manufacturing fit.

At the default Ø120 mm pole, the exported generic pulley, metal-hardware and line-route meshes had less than 0.001 mm³ overlap with either mount half. The default front/rear solid volumes were 357,917.151 / 264,313.526 mm³. These are full-solid CAD volumes, not print-mass estimates.

Assembled and exploded previews were rendered from the actual exported meshes and visually inspected. The GLB is an assembly reference, including purchased hardware envelopes; it is not a fabrication mesh. The builder emits source SHA-256 hashes with its geometry report in the ignored output folder.

Local verification

Check Result on 7 October 2026
pnpm cad:check -- --require-openscad Passed: all 71 registered models compiled with OpenSCAD 2021.01
python scripts/build-pole-pulley-concept.py Passed: six custom-part meshes, nominal interface checks, CAD renders, GLB and ZIP
pnpm bom:generate then pnpm bom:check Passed; 234 existing report incompleteness warnings; baseline build quantities and costs unchanged
pnpm docs:check Passed: 171 Markdown files
git diff --check Passed
Invalid assembly overrides Ø80 pole, zero split gap and 10 mm clevis gap rejected by assertions
Portable source pack ZIP integrity passed; extracted assembly compiled independently to CSG
Reused output directory Fresh build excluded a deliberately pre-existing obsolete STL; ZIP contained only the 16 current generated artifacts
GLB scale and provenance Z envelope 0.310 m; all recorded CAD source hashes matched

These are local checks. No CI run, fabricated prototype or physical inspection is claimed by this record.

Scope of the result

These checks cover nominal static CAD at three pole diameters. They do not simulate closure of the split collar, friction, deflection, bolt preload, pole taper/ovality, printing, material strength, articulation under changing line angles, full drum travel, keeper retention or weather exposure. The purchased pulley has not been selected or measured. This record does not promote the model above concept-unvalidated and does not replace the through-bolt baseline.