Edge diagnostic retention and reconnect host evidence

  • Date: 2026-10-11
  • Work record: #51
  • Revision: source/tests in this PR; its merge commit identifies the accepted revision
  • Host: isolated Linux x86-64, Node 24.19.0, pinned pnpm 11.5.2, native SQLite and PostgreSQL 18.4
  • Inputs: synthetic protocol/capabilities, private temporary files, generated isolated signing keys; no live credentials

The diagnostic suite passed nine tests, including authenticated TLS observation, bounded synchronous floods, reserved fault history, clock/boot changes, unsupported measured sensing, closed-schema secret/text rejection, expiration, current export authorization/cancellation, frozen snapshots, concurrent export limits, low-data/essential-only modes, unknown coverage, exhausted quota, durable debit before transport, lost receipts, stalled callbacks and private-file/ownership/corruption checks.

The sixty-second disconnected soak uses a 64-record, 64 KiB logical, 64-page ring and 100-input bursts with an event-loop yield between bursts. Recorded source evidence:

Observation Result
Duration 60,006 ms
Diagnostic inputs 1,084,300
Peak process RSS 229,838,848 bytes (219.2 MiB)
Peak diagnostic directory size 65,536 bytes
Maximum simulated stop-timer delay 19.640 ms
Timer callbacks 5,220
Retained / logical bytes 32 / 38,720
Accepted / dropped / uploaded / rejected 10,858 / 1,084,268 / 0 / 0
Volatile losses / degraded storage 0 / false

These are actual measurements on this selected prototype host. The timer represents a simulated local stop scheduler; it is not a physical GPIO/watchdog latency measurement or a hard real-time guarantee. Limits of 512 MiB RSS and 1,000 ms timer delay are test regression ceilings, not production safety requirements.

The native reconnect test uses the actual edge pump, SQLite job audit relay/transfer ledger, signed HTTP ingest handler and fresh native PostgreSQL schema. The first event commits while its response is lost. After storage/process-epoch reconstruction, two original old-boot events reach cloud storage in three attempts, with two authoritative rows. Actor, site, device, boot/session, command links and original source clocks compare exactly. Missing sequence 2 and disjoint clock uncertainty remain visible. The test exhausts discretionary quota with unknown WAN coverage while bounded essential audit replay succeeds. The full native dashboard slice passes 44/44 tests.

The shared audit suite passes six tests, including native SIGKILL/SQLite-full recovery and bounded prefix corruption/receipt checks. Edge and dashboard build/type checks, ordinary dashboard regressions, HTTP contracts, docs/whitespace checks and the full CI matrices provide additional source evidence. The existing local systemd check cannot run because this host lacks /usr/bin/node; Linux CI stages its pinned executable and runs that check.

No selected Pi/Pico, installed sensor, actual cellular connection, production notification/media/recording service, privileged kernel shaping, physical storage interruption or carrier bill was exercised. Cloud/edge adapters stay opt-in and simulation-only.