Assembly diagnostics host and browser evidence
- Date: 2026-10-11
- Work record: #48
- Revision: source/tests in this PR; its merge commit identifies the accepted revision
- Host: isolated Linux x86-64, Node 24.19.0, pinned pnpm 11.5.2
- Data: committed bounded plant/configuration fixtures and temporary native PostgreSQL
- Browser: Playwright 1.58.2, Chromium 145; private ephemeral test session; no live credentials
The projection tests verify all baseline assemblies, passive/unavailable sensing, declared measurement capability, stale original quality, old/repeated samples, missing sequence intervals, source/revision reset, 60-point retention and nested export redaction. Protected API tests exercise current authorization, cross-site/role denial, invalid units/mixed versions, response bounds, selected fault/command adapter bounds and post-read revocation.
The built application browser suite verifies all operational screens and current session/directory behavior. Its selected diagnostics story opens all 19 inventory rows, starts only the chosen pod detail, checks source quality, then hides/closes demand and downloads the redacted bounded export. Native redirect/protection-header checks remain separate from this isolated application identity. Mobile width is checked at 390 pixels; the screenshot is a local test artifact, not committed binary output.
The first full browser run passed 9/9 checks. The final source adds explicit optional fault-history projection and counts bytes only after a response completes; cancelled responses cannot produce a false completed-payload receipt.
Final source validation: dashboard lint/typecheck/build passed; ordinary dashboard tests passed 65 assertions with 10 explicit native-only skips; the independent native PostgreSQL suite passed 28/28 with no skips. The selected-diagnostics/all-screen browser regression passed 2/2 checks; after the mobile table and measurement-fixture correction, the final focused check passed 1/1, including 390-pixel width, hidden/closed demand and nested redaction. It measured 8,709 JSON response bytes over three completed selected requests, with zero periodic detail requests for overview, hidden or closed views. Built ordinary/branch-preview HTTP checks and documentation/whitespace checks passed. The mobile provenance table uses the existing horizontal scroll container rather than compressing source identities into unreadable columns.
This measures JSON application payload and browser lifecycle, not HTTP/TLS/carrier bytes, real garden uplink demand, physical sensing or installed-system behavior. The snapshot/chart source is an explicitly bounded synthetic plant. Configured firmware references and chart motion cannot establish installed firmware or calibrated safety.